Four pole distribution blocks
Four pole distribution blocks - RPQ
Four pole distribution blocks - RPQ 160A
Distribution Blocks - RPQ1025
RPQ1051 distributors
Four pole distribution blocks - RPQ
Technical Characteristics
Insulating block: PA 6, UL 94-V0, halogen-free, grey RAL 7035
Protective screen: PC, UL 94-V2, transparent yellow, manually removable
Conduction block: brass
Screws: steel
IP10 degree of protection, provides protection in case of accidental contact
Quick hook-up on DIN rails
Compliant with standard EN 60947-7-1
RPQ0980, RPQ0985, RPQ0990 and RPQ0995
– Maximum temperature of continuous operation:
+ 105 ° C
RPQ1000, RPQ1005 and RPQ1010
– Maximum temperature of continuous operation:
+ 85 ° C – Halogen-free
← | → | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Code | Reference | L (mm) | H (mm) | P (mm) | Hole spacing fixing (mm) | ||||||||||
+ | RPQ0980 | RPQ 40-08 | 66 | 84 | 50 | 45 | |||||||||
Specifications: |
|||||||||||||||
+ | RPQ0985 | RPQ 40-14 | 100 | 84 | 50 | 80 | |||||||||
Specifications: |
|||||||||||||||
+ | RPQ0990 | RPQ 80-07 | 66 | 84 | 50 | 45 | |||||||||
Specifications: |
|||||||||||||||
+ | RPQ0995 | RPQ 80-12 | 100 | 84 | 50 | 80 | |||||||||
Specifications: |
|||||||||||||||
+ | RPQ1000 | RPQ 125-06 | 66 | 84 | 50 | 45 | |||||||||
Specifications: |
|||||||||||||||
+ | RPQ1005 | RPQ 125-10 | 100 | 84 | 50 | 80 | |||||||||
Specifications: |
|||||||||||||||
+ | RPQ1010 | RPQ 125-14 | 132 | 84 | 50 | 112 | |||||||||
Specifications: |
Four pole distribution blocks - RPQ 160A
Technical Characteristics
Insulating block: PA 6, UL 94-V0, grey RAL 7035
Protective screen: PC, UL 94-V2, transparent yellow, manually removable
Conduction block: brass
Screws: steel
IP10 degree of protection, provides protection in case of accidental contact
Quick hook-up on DIN rails
Compliant with standard EN 60947-7-1
RPQ1015, RPQ1016 and RPQ1017
– Maximum temperature of continuous operation:
+ 85 ° C
RPQ1018
– Maximum temperature of continuous operation:
+ 85 ° C
– Halogen free
ADVANTAGES
Separate entrances
Forged conductors
Easy wiring: RPQ1015, RPQ1018
Modular depth: RPQ1016, RPQ1017
RPQ1016: Up & Down version – connection of 2 phases per side
RPQ1018: Side Input version – inputs orthogonal to the outputs
← | → | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Code | Reference | L (mm) | H (mm) | P (mm) | Hole spacing fixing (mm) | ||||||||||
+ | RPQ1015 | RPQ 160-11 | 168 | 85 | 70 | 147 | |||||||||
Specifications: |
|||||||||||||||
+ | RPQ1016 | RPQ 160-11-U&D | 176 | 105 | 55 | 163 | |||||||||
Specifications: |
|||||||||||||||
+ | RPQ1017 | RPQ 160-11 MS | 176 | 105 | 55 | 163 | |||||||||
Specifications: |
|||||||||||||||
+ | RPQ1018 | RPQ 160-11 YES | 154 | 95 | 67 | 135 | |||||||||
Specifications: |
RPQ1025 distributors
Technical Characteristics
Insulating block: PA 6, UL 94-V0, grey RAL 7035
Protective screen: PC, UL 94-V2, transparent yellow, removable with flat-head screwdriver
Conduction block: brass
Screws: steel
IP20 protection degree
Quick hook-up on DIN rails
Compliant with standard EN 60947-7-1
RPQ1025
– Maximum temperature of continuous operation:
+ 85 ° C
– Facilitated wiring
ADVANTAGES
Wiring with cables with or without terminal
Inspection of the wiring and verification of the connection
← | → | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Code | Reference | L (mm) | H (mm) | P (mm) | Hole spacing fixing (mm) | ||||||||||
+ | RPQ1025 | RPQ C-125 | 98 | 75 | 49 | 55 - 70 | |||||||||
Specifications: |
RPQ1051 distributors
Technical Characteristics
Structure: PA 6, UL 94-V0, grey RAL 7035
Protective screen: PC, UL 94-V2, transparent yellow, manually removable
Conduction block: tinned copper
Screws: steel
IP10 degree of protection, provides protection in case of accidental contact
Quick coupling on DIN rails or installation on panels with screws
Compliant with standard EN 60947-7-1
RPQ1051
– Maximum temperature of continuous operation:
+ 85 ° C
– Halogen free
ADVANTAGES
Ease of connection: the inputs are separated from the outputs
Input connections for: COFLEX, COFLEX PLUS, JLINK, JLINK PLUS and cables with lugs
Wiring from both sides with cables with or without terminal
Inspection of the wiring and verification of the connection
Complete product customization:
– All 4-POLE bars can be oriented with left or right input
– Inlet bars can be fixed from the right or left, front or rear.
← | → | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Code | Reference | L (mm) | H (mm) | w (mm) | Hole spacing fixing (mm) | ||||||||||
+ | RPQ1051 | RPQ 400-14 | 194 (264 with terminals) | 141 | 165 | 128 | |||||||||
Specifications: |
The ΩWARE software facilitates the sizing of the electrical panel, saves time and minimizes the possibility of error